Xserve homepage [ logo ]
 

 







AccuSTOR S3150 ( FC to SCSI )

AccuSTOR S3150

 

Tell me more

Features

  • Standalone host and OS independent, RAID SCSI-to-SCSI storage system
  • Massive storage capacity, up to 2 terabytes, with a maximum of 15 LVD hard disks
  • Redundant power supplies (Three 300 Watt modules) and fans (Three large blower modules and 6 regular fans)
  • Freestanding tower or rack mount deployments
  • Hot-swappable hard disks, power supplies system air blowers and fans
  • Cable-free design reduces signal length, improves data throughput
  • Supports RAID level 0, 1(0+1), 3, 5, 10, 30, 50
  • Enhanced vibration technology for hard disk drive motion protection
SCSI-SCSI entry
SCSI-SCSI Performance
SCSI-SCSI Redundent
FC-SCSI

Technical Specifications: ( FC to SCSI )

AS-2500-10

Model No.
AS-2500-10

RAID Controller

RAID controller I/O Processor

PowerPC 750Cxe 64-bit
RISC I/O Processor (s)

Cache Memory

128MB~1GB maximum cache size on single SDRAM DIMM socket with ECC supported

Supported RAID Levels

0, 1, 0+1, 3, 5, 10, 30, 50, JBOD

Scalability

Up to 8 Logic Drive of variable RAID levels

Host Channels/Maximum Channel

Fibre Channel 1G*2 pluse 4 SCSI Ultra 160

On-line RAID Expansion

yes

System

Backplane Board Interface

SCSI Ultra 160/320

Number of drives per enclosure

15

Drive Form Factor

1" High

Hard Disk Capacity Supported

18GB/ 36GB/ 73GB/ 146GB

Max Capacity/Maximum Storage Capacity per Enclosure

10TB/Up to 2TB per enclosure

High Availability

Redundant & Hot-swappable

Fans, Power Supplies, Hard Disk Drives

Hot-spare Driver support

Local/Global Spare Hard Disk

System Chassis

Dimensions / Weight

133 mm H x 600 mm D x 480 mm W

Rack Density/Height

19"Rack mount 3U high

Rack-mount Kit

Yes

Weight

35Kgs

Management

Environments Management Control

Hard Disk, Fan, Power, Temperature Status

Enclosed LED Indicators

Yes

Automatic Failed Drive Protector and failed drive rebuild

Yes

Drive LED Indicators

Yes

Remote Instrumentation

SNMP/E-mail Supported

Management Tools

i-STOR Mgt.

Clustering Certification

Windows NT/2000, HP-UX, IBM AIX, SUN Solaris, LInux, SCO System

Regulatory & Environment

EMI/Safety

FCC class A, BSMI, CE, VCCI, TUV and CCC

Temperate Range

10°C to 40°C; 8% to 80% non-condensing humidity;
Maximum wet bulb 27 °C

Power

Power: 90 to 260 VAC (47 to 63 Hz line frequency), 600W at max. Average


Top

AS-2500-20

Model No.
AS-2500-20

RAID Controller

RAID controller I/O Processor

PowerPC 750Cxe 64-bit
RISC I/O Processor (s)

Cache Memory

128MB~1GB maximum cache size on single SDRAM DIMM socket with ECC supported

Supported RAID Levels

0, 1, 0+1, 3, 5, 10, 30, 50, JBOD

Scalability

Up to 8 Logic Drive of variable RAID levels

Host Channels/Maximum Channel

Fibre Channel 2G*2 pluse 4 SCSI Ultra 160

On-line RAID Expansion

yes

System

Backplane Board Interface

SCSI Ultra 160/320

Number of drives per enclosure

15

Drive Form Factor

1" High

Hard Disk Capacity Supported

18GB/ 36GB/ 73GB/ 146GB

Max Capacity/Maximum Storage Capacity per Enclosure

10TB/Up to 2TB per enclosure

High Availability

Redundant & Hot-swappable

Fans, Power Supplies, Hard Disk Drives

Hot-spare Driver support

Local/Global Spare Hard Disk

System Chassis

Dimensions / Weight

133 mm H x 600 mm D x 480 mm W

Rack Density/Height

19"Rack mount 3U high

Rack-mount Kit

Yes

Weight

35Kgs

Management

Environments Management Control

Hard Disk, Fan, Power, Temperature Status

Enclosed LED Indicators

Yes

Automatic Failed Drive Protector and failed drive rebuild

Yes

Drive LED Indicators

Yes

Remote Instrumentation

SNMP/E-mail Supported

Management Tools

i-STOR Mgt.

Clustering Certification

Windows NT/2000, HP-UX, IBM AIX, SUN Solaris, LInux, SCO System

Regulatory & Environment

EMI/Safety

FCC class A, BSMI, CE, VCCI, TUV and CCC

Temperate Range

10°C to 40°C; 8% to 80% non-condensing humidity;
Maximum wet bulb 27 °C

Power

Power: 90 to 260 VAC (47 to 63 Hz line frequency), 600W at max. Average


Top