AccuSTOR S3150 ( SCSI to SCSI Entry )
|
|
Features
- Standalone host and OS independent, RAID SCSI-to-SCSI storage system
- Massive storage capacity, up to 2 terabytes, with a maximum of 15 LVD hard disks
- Redundant power supplies (Three 300 Watt modules) and fans (Three large blower modules and 6 regular fans)
- Freestanding tower or rack mount deployments
- Hot-swappable hard disks, power supplies system air blowers and fans
- Cable-free design reduces signal length, improves data throughput
- Supports RAID level 0, 1(0+1), 3, 5, 10, 30, 50
- Enhanced vibration technology for hard disk drive motion protection
|
|
Technical Specifications: ( SCSI to SCSI Entry )
AS - 2200
| Model No. |
AS-2200 |
RAID Controller |
RAID controller I/O Processor |
PowerPC 603e 64-bit
RISC I/O Processor (s) |
Cache Memory |
128MB~1GB maximum cache size on single SDRAM DIMM socket with ECC supported |
Supported RAID Levels |
0, 1, 0+1, 3, 5, 10, 30, 50, JBOD |
Scalability |
Up to 8 Logic Drive of variable RAID levels |
Host Channels/Maximum Channel |
2/4/6 Host channel |
On-line RAID Expansion |
yes |
System |
Backplane Board Interface |
SCSI Ultra 160/320 |
Number of drives per enclosure |
15 |
Drive Form Factor |
1" High |
Hard Disk Capacity Supported |
18GB/ 36GB/ 73GB/ 146GB |
Max Capacity/Maximum Storage Capacity per Enclosure |
10TB/Up to 2TB per enclosure |
High Availability |
Redundant & Hot-swappable |
Fans, Power Supplies, Hard Disk Drives |
Hot-spare Driver support |
Local/Global Spare Hard Disk |
System Chassis |
Dimensions / Weight |
133 mm H x 600 mm D x 480 mm W |
Rack Density/Height |
19"Rack mount 3U high |
Rack-mount Kit |
Yes |
Weight |
35Kgs |
Management |
Environments Management Control |
Hard Disk, Fan, Power, Temperature Status |
Enclosed LED Indicators |
Yes |
Automatic Failed Drive Protector and failed drive rebuild |
Yes |
Drive LED Indicators |
Yes |
Remote Instrumentation |
SNMP/E-mail Supported |
Management Tools |
i-STOR Mgt. |
Clustering Certification |
Windows NT/2000, HP-UX, IBM AIX, SUN Solaris, LInux, SCO System |
Regulatory & Environment |
EMI/Safety |
FCC class A, BSMI, CE, VCCI, TUV and CCC |
Temperate Range |
10°C to 40°C; 8% to 80% non-condensing humidity;
Maximum wet bulb 27 °C |
Power |
Power: 90 to 260 VAC (47 to 63 Hz line frequency), 600W at max. Average |
Top
AS - 2300
| Model No. |
AS-2300 |
RAID Controller |
RAID controller I/O Processor |
PowerPC 603e 64-bit
RISC I/O Processor (s)
|
Cache Memory |
128MB~1GB maximum cache size on single SDRAM DIMM socket with ECC supported |
Supported RAID Levels |
0, 1, 0+1, 3, 5, 10, 30, 50, JBOD |
Scalability |
Up to 8 Logic Drive of variable RAID levels |
Host Channels/Maximum Channel |
2/4/6 Host channel |
On-line RAID Expansion |
yes |
System |
Backplane Board Interface |
SCSI Ultra 160/320 |
Number of drives per enclosure |
15 |
Drive Form Factor |
1" High |
Hard Disk Capacity Supported |
18GB/ 36GB/ 73GB/ 146GB |
Max Capacity/Maximum Storage Capacity per Enclosure |
10TB/Up to 2TB per enclosure |
High Availability |
Redundant & Hot-swappable |
Fans, Power Supplies, Hard Disk Drives |
Hot-spare Driver support |
Local/Global Spare Hard Disk |
System Chassis |
Dimensions / Weight |
133 mm H x 600 mm D x 480 mm W |
Rack Density/Height |
19"Rack mount 3U high |
Rack-mount Kit |
Yes |
Weight |
35Kgs |
Management |
Environments Management Control |
Hard Disk, Fan, Power, Temperature Status |
Enclosed LED Indicators |
Yes |
Automatic Failed Drive Protector and failed drive rebuild |
Yes |
Drive LED Indicators |
Yes |
Remote Instrumentation |
SNMP/E-mail Supported |
Management Tools |
i-STOR Mgt. |
Clustering Certification |
Windows NT/2000, HP-UX, IBM AIX, SUN Solaris, LInux, SCO System |
Regulatory & Environment |
EMI/Safety |
FCC class A, BSMI, CE, VCCI, TUV and CCC |
Temperate Range |
10°C to 40°C; 8% to 80% non-condensing humidity;
Maximum wet bulb 27 °C |
Power |
Power: 90 to 260 VAC (47 to 63 Hz line frequency), 600W at max. Average |
Top
|
|